Dispensing NuSil CV-2946

NuSil · 2K thermal adhesive · 1.49 W/m·K

NuSil CV-2946 is a silicone 2K thermal adhesive from NuSil, rated 1.49 W/m·K. Typical uses: Low-outgassing heat transfer to heat sinks; bonding IC substrates/base plates (space/aerospace). Short answer: we dispense it with a PDP two-component progressive cavity metering pump with a static mixer.

Material at a glance

ManufacturerNuSil
Type2K thermal adhesive
ChemistrySilicone
Thermal conductivity1.49 W/m·K
Mix ratio15:1 (A:B)
Viscosity3,560,000 cP
CureListed as 7 days RTV (work time 2 h); page also says heat-cure - verify

From the manufacturer's published data (source). Always work from the current technical data sheet.

How we dispense it

For a two-component thermally conductive adhesive we start with a PDP two-component progressive cavity metering pump and a disposable static mixer, fed from dual cartridges for lab and low volume, or from pails with a follower-plate pail pump for production. Pump size depends on your shot or bead size and cycle time.

  • Abrasion: the ceramic filler that carries the heat wears pumps out. We use tungsten carbide rotors and wear-resistant stators and run the pump slowly, at 8 to 12 rpm, for long wear life.
  • Ratio: each side is metered by its own progressive cavity pump to within ±1%. Check ratio by weighing a shot from each side every week, because filled materials vary from batch to batch.
  • Mixing: a disposable static mixer does the mixing. Purge or change it before the material's working life runs out.

See our PDP two-component metering pumps, or use the pump configurator.

Frequently asked questions

What pump should I use to dispense NuSil CV-2946?

For a two-component thermally conductive adhesive we start with a PDP two-component progressive cavity metering pump and a disposable static mixer, fed from dual cartridges for lab and low volume, or from pails with a follower-plate pail pump for production. Pump size depends on your shot or bead size and cycle time; send us those and we will size it.

Can NuSil CV-2946 be fed from pails instead of cartridges?

Cartridges suit lab and low volume. Above that, a follower-plate pail pump feeds the metering pump directly, which cuts container changes and waste.

How do you keep NuSil CV-2946 on ratio?

Each side is metered by its own progressive cavity pump, held to within ±1% per side. We recommend a weekly check: weigh a shot from each side and adjust, because filled materials vary from batch to batch.

Will NuSil CV-2946 wear out the pump?

Thermally conductive fillers are abrasive. With tungsten carbide rotors, wear-resistant stators and pump speeds of 8 to 12 rpm, stators typically last 6 to 12 months and rotors up to 24 months, and a pump rebuild takes under an hour.

Talk it through with us

Running NuSil CV-2946, or about to? Send us the technical data sheet, your bead or shot size and your cycle time, and we'll recommend a pump and feed system. We can run an application test on your material before you buy. Contact us

Related materials

All thermal interface materials · Materials we've dispensed

NuSil CV-2946 is a trademark of NuSil or its affiliates. Dispense Robotics is not affiliated with the manufacturer; the name is used to describe the material our equipment dispenses.