Electrolube TCOR is a silicone 1K thermal adhesive from Electrolube, rated 1.8 W/m·K. Typical uses: Device-to-heat-sink gap filling, around power resistors; low-strength adhesive/sealant/gasket. Short answer: we dispense it with a PCP progressive cavity pump.
Material at a glance
| Manufacturer | Electrolube |
|---|---|
| Type | 1K thermal adhesive |
| Chemistry | Silicone |
| Thermal conductivity | 1.8 W/m·K |
| Viscosity | 140-150 Pa·s at 1 rpm (non-slump paste) |
| Cure | Moisture cure (oxime RTV): skin 10-15 min, full cure 24 h at 20°C |
| Packages | TCOR75S 75 ml syringe pack |
From the manufacturer's published data (source). Always work from the current technical data sheet.
How we dispense it
For a single-component thermally conductive adhesive we start with a PCP progressive cavity pump, fed from a cartridge for lab and low volume, or from a pail with a follower-plate pail pump for production. A progressive cavity pump meters by volume, so dot and bead size stay consistent. Pump size depends on your dot or bead size and cycle time.
- Abrasion: the ceramic filler that carries the heat wears pumps out. We use tungsten carbide rotors and wear-resistant stators and run the pump slowly, at 8 to 12 rpm, for long wear life.
- Moisture cure: keep the feed sealed from air, or the material skins in the lines.
See our PCP progressive cavity pumps, or use the pump configurator.
Frequently asked questions
What pump should I use to dispense Electrolube TCOR?
For a single-component thermally conductive adhesive we start with a PCP progressive cavity pump, fed from a cartridge for lab and low volume, or from a pail with a follower-plate pail pump for production. Pump size depends on your shot or bead size and cycle time; send us those and we will size it.
Can Electrolube TCOR be fed from pails instead of cartridges?
Electrolube lists these packages: TCOR75S 75 ml syringe pack. Cartridges suit lab and low volume. Above that, a follower-plate pail pump feeds the metering pump directly, which cuts container changes and waste.
Does Electrolube TCOR need mixing?
No. It is a single-component material, so there is no mixer and no ratio to hold. The job is accurate, repeatable volumetric metering, which is what a progressive cavity pump does.
Will Electrolube TCOR wear out the pump?
Thermally conductive fillers are abrasive. With tungsten carbide rotors, wear-resistant stators and pump speeds of 8 to 12 rpm, stators typically last 6 to 12 months and rotors up to 24 months, and a pump rebuild takes under an hour.
Talk it through with us
Running Electrolube TCOR, or about to? Send us the technical data sheet, your bead or shot size and your cycle time, and we'll recommend a pump and feed system. We can run an application test on your material before you buy. Contact us
Related materials
- ER6003 thermally conductive epoxy · Electrolube, 2K thermally conductive adhesive
- BERGQUIST LIQUI BOND TLB SA2000 (Liqui-Bond SA 2000) · Henkel Bergquist, 1K thermal adhesive
- LOCTITE TLB 9300 APSi · Henkel Loctite, 2K thermal adhesive (structural, EV battery)
- LOCTITE TLB 9270APS · Henkel Loctite, 2K thermal adhesive (EV battery)
- CoolTherm UR-2000 · Parker LORD, 2K gap filler / thermal adhesive
- CoolTherm TC-2002 · Parker LORD, 2K thermal adhesive (structural)
All thermal interface materials · Materials we've dispensed
Electrolube TCOR is a trademark of Electrolube or its affiliates. Dispense Robotics is not affiliated with the manufacturer; the name is used to describe the material our equipment dispenses.

