SARCON SPG-70A is a silicone 1K thermal gel (form-in-place) from Fujipoly, rated 7.0 W/m·K. Typical uses: Form-in-place gap filler between heat sources and heat sinks/spreaders; gaps down to 0.2 mm. Short answer: we dispense it with a PCP progressive cavity pump.
Material at a glance
| Manufacturer | Fujipoly |
|---|---|
| Type | 1K thermal gel (form-in-place) |
| Chemistry | Silicone |
| Thermal conductivity | 7.0 W/m·K |
| Cure | No heat curing required |
| Packages | 30cc syringe; 325cc cartridge; custom |
From the manufacturer's published data (source). Always work from the current technical data sheet.
How we dispense it
For a single-component thermal gel we start with a PCP progressive cavity pump, fed from a cartridge for lab and low volume, or from a pail with a follower-plate pail pump for production. A progressive cavity pump meters by volume, so dot and bead size stay consistent. Pump size depends on your dot or bead size and cycle time.
- Abrasion: the ceramic filler that carries the heat wears pumps out. We use tungsten carbide rotors and wear-resistant stators and run the pump slowly, at 8 to 12 rpm, for long wear life.
- Feed: thick pastes don't flow to a pump on their own. Above cartridge volumes, a follower plate pushes the material out of the pail and keeps air out.
See our PCP progressive cavity pumps, or use the pump configurator.
Frequently asked questions
What pump should I use to dispense SARCON SPG-70A?
For a single-component thermal gel we start with a PCP progressive cavity pump, fed from a cartridge for lab and low volume, or from a pail with a follower-plate pail pump for production. Pump size depends on your shot or bead size and cycle time; send us those and we will size it.
Can SARCON SPG-70A be fed from pails instead of cartridges?
Fujipoly lists these packages: 30cc syringe; 325cc cartridge; custom. Cartridges suit lab and low volume. Above that, a follower-plate pail pump feeds the metering pump directly, which cuts container changes and waste.
Does SARCON SPG-70A need mixing?
No. It is a single-component material, so there is no mixer and no ratio to hold. The job is accurate, repeatable volumetric metering, which is what a progressive cavity pump does.
Will SARCON SPG-70A wear out the pump?
Thermally conductive fillers are abrasive. With tungsten carbide rotors, wear-resistant stators and pump speeds of 8 to 12 rpm, stators typically last 6 to 12 months and rotors up to 24 months, and a pump rebuild takes under an hour.
Talk it through with us
Running SARCON SPG-70A, or about to? Send us the technical data sheet, your bead or shot size and your cycle time, and we'll recommend a pump and feed system. We can run an application test on your material before you buy. Contact us
Related materials
- SARCON SPG-50A · Fujipoly, 1K thermal gel (form-in-place)
- SARCON SPG-30B · Fujipoly, 1K thermal gel (form-in-place)
- SARCON SPG-20B · Fujipoly, 1K thermal gel (form-in-place)
- BERGQUIST LIQUI FORM TLF LF2000 (Liqui-Form 2000) · Henkel Bergquist, 1K thermal gel
- BERGQUIST LIQUI FORM TLF LF3500 (Liqui-Form 3500) · Henkel Bergquist, 1K thermal gel
- BERGQUIST LIQUI FORM TLF 6000HG · Henkel Bergquist, 1K thermal gel
All thermal interface materials · Materials we've dispensed