Products Details
The communication control function (MODBUS) allows you to set the parameter and monitoring on the parent PC.
External shot signals can be answered without delay for dispensing of accurate and control.
The variable speed can be applied and channels can be changed while the system is in operation, so it is more responsive to various dispensing condition and change.
Applications with various sensors such as pressure sensors, residual sensors and flow sensors can be implemented.
Various dispensing conditions can be set through the three operating mode(TIME/STEADY/METERING).
Specification
Dimension | 216 x 100 x 43 mm |
Weight | 552 gr |
Power | DC 24V |
Power Consumption | Max 5A |
Power (SMPS) | AC220V, 50/60Hz |
Operating Method | Time, Steady, Mix Ratio |
Control | Parent PLC Communication (RS232C) or HMI |
Comm. Control | MODBUS (ASCII) - MODBUS LRC |
Available PRO-PUMP | PCP-005, PCP-015, PCP-050 PCP-150, PCP-500, PCP-1000 |
No resources for this product.